05GP SERIES
GRAVURE PRINTING · HEAT RECOVERY SYSTEM
BSE-GP55
Large-capacity vertical heat-recovery system for high-speed printing and T-die processes
A large-capacity GP Series model with a wide airflow range and a 15 HP fan, configurable for the required process temperature.
Vertical designLow-Temperature (L) / High-Temperature (H)Large capacity
GP55

TECHNICAL SPECIFICATIONSBSE-GP55
BSE-GP55
Technical specifications
The L/H specifications and filter dimensions below are based on E-SAVER Specification Sheet Ver. 4.6. Values may vary according to site conditions and custom-order requirements.
NoteFan design airflow and static pressure are specified separately from maximum operating values.
| Item | BSE-GP55-L | BSE-GP55-H | ||
|---|---|---|---|---|
| Applicable process equipment | 500 m/min gravure printing press / T-die line | 500 m/min gravure printing press / T-die line | ||
| Maximum operating temperature (°C) | 100℃ | 120℃ | ||
| Filter | Optional specification | Pre-filter | 580 × 900 × 20T 2EA | 580 × 900 × 20T 2EA |
| Medium filter | 580 × 900 × 75T 2EA / D · M | 580 × 900 × 75T 2EA / D · M | ||
| Optional specification | Demister filter | 580 × 900 × 40T 2EA | 580 × 900 × 40T 2EA | |
| PVC bag filter | 793 × 455 × 5T 1EA | 793 × 455 × 5T 1EA | ||
| Fan motor | Motor rating (HP) | 15 HP | 15 HP | |
| Motor power (kW) | 11 kW | 11 kW | ||
| Fan shaft power (kW) | 8.10 kW | 8.10 kW | ||
| Average power consumption / maximum connected load | Average: 40 kW (maximum: 50 kW) | Average: 60 kW (maximum: 80 kW) | ||
| Heat capacity (kcal/h) | 235,000 | 270,000 | ||
| Fan design airflow (CMM, m³/min) | 60–250 | 60–250 | ||
| Fan design static pressure (mmAQ) | 60–200 | 60–200 | ||