KR
09CO SERIES
COATING PROCESS · HEAT RECOVERY SYSTEM

BSE-CO02

Horizontal heat-recovery system for compact high-temperature coating lines

A compact CO Series model for coating processes requiring high-temperature operation and controlled airflow.

Horizontal designLow-Temperature (L) / High-Temperature (H)For coating lines
CO02E-SAVER BSE-CO02 heat recovery system
TECHNICAL SPECIFICATIONS

BSE-CO02
Technical specifications

The L/H specifications and filter dimensions below are based on E-SAVER Specification Sheet Ver. 4.6. Values may vary according to site conditions and custom-order requirements.

NoteFan design airflow and static pressure are specified separately from maximum operating values.
ItemBSE-CO02HOR-LBSE-CO02HOR-H
Applicable process equipmentCoating lineCoating line
Maximum operating temperature (°C)200℃250℃
FilterOptional
specification
Pre-filter610 × 610 × 20T
1EA
610 × 610 × 20T
1EA
Medium filter610 × 610 × 75T
1EA / M
610 × 610 × 75T
1EA / HM
Optional
specification
Demister filter610 × 610 × 40T
1EA
610 × 610 × 40T
1EA
PVC bag filter300 × 480 × 5T
1EA
300 × 480 × 5T
1EA
Fan
motor
Motor rating (HP)5 HP5 HP
Motor power (kW)3.7 kW3.7 kW
Fan shaft power (kW)2.64 kW2.64 kW
Average power consumption / maximum connected loadAverage: 38 kW (maximum: 50 kW)Average: 50 kW (maximum: 65 kW)
Heat capacity (kcal/h)95,000108,000
Fan design airflow (CMM, m³/min)20–8020–80
Fan design static pressure (mmAQ)40–15040–150
PREVIOUS MODEL← BSE-DL32NEXT MODELBSE-CO12