KR
08DL SERIES
DRY LAMINATION · HEAT RECOVERY SYSTEM

BSE-DL32

High-capacity horizontal heat-recovery system for dry lamination

A higher-capacity DL Series model for demanding lamination conditions, configurable with standard or high-temperature options.

Horizontal designStandard (L) / High-Temperature (H)High capacity
DL32E-SAVER BSE-DL32 heat recovery system
TECHNICAL SPECIFICATIONS

BSE-DL32
Technical specifications

The L/H specifications and filter dimensions below are based on E-SAVER Specification Sheet Ver. 4.6. Values may vary according to site conditions and custom-order requirements.

NoteFan design airflow and static pressure are specified separately from maximum operating values.
ItemBSE-DL32HOR-LBSE-DL32HOR-H
Applicable process equipmentDry lamination lineDry lamination line
Maximum operating temperature (°C)100℃130℃
FilterOptional
specification
Pre-filter610 × 500 × 20T
2EA
610 × 500 × 20T
2EA
Medium filter610 × 500 × 75T
2EA / D · M
610 × 500 × 75T
2EA / D · M
Optional
specification
Demister filter610 × 500 × 40T
2EA
610 × 500 × 40T
2EA
PVC bag filter320 × 615 × 5T
1EA
320 × 615 × 5T
1EA
Fan
motor
Motor rating (HP)10 HP10 HP
Motor power (kW)7.5 kW7.5 kW
Fan shaft power (kW)6.20 kW6.20 kW
Average power consumption / maximum connected loadAverage: 40 kW (maximum: 48.75 kW)Average: 60 kW (maximum: 67.5 kW)
Heat capacity (kcal/h)185,000244,000
Fan design airflow (CMM, m³/min)20–18020–180
Fan design static pressure (mmAQ)60–18060–180
PREVIOUS MODEL← BSE-DL22NEXT MODELBSE-CO02