KR
02GP SERIES
GRAVURE PRINTING · HEAT RECOVERY SYSTEM

BSE-GP32

Vertical heat-recovery drying system for 300 m/min gravure printing

Designed for the airflow and static-pressure requirements of 300 m/min printing lines, with low- and high-temperature configurations for the required drying conditions.

Vertical designLow-Temperature (L) / High-Temperature (H)For gravure printing
GP32E-SAVER BSE-GP32 heat recovery system
TECHNICAL SPECIFICATIONS

BSE-GP32
Technical specifications

The L/H specifications and filter dimensions below are based on E-SAVER Specification Sheet Ver. 4.6. Values may vary according to site conditions and custom-order requirements.

NoteFan design airflow and static pressure are specified separately from maximum operating values.
ItemBSE-GP32-LBSE-GP32-H
Applicable process equipment300 m/min gravure printing press300 m/min gravure printing press
Maximum operating temperature (°C)100℃120℃
FilterOptional
specification
Pre-filter610 × 762 × 20T
1EA
610 × 762 × 20T
1EA
Medium filter610 × 762 × 75T
1EA / D · M
610 × 762 × 75T
1EA / D · M
Optional
specification
Demister filter610 × 762 × 40T
1EA
610 × 762 × 40T
1EA
PVC bag filter240 × 693 × 5T
1EA
240 × 693 × 5T
1EA
Fan
motor
Motor rating (HP)7.5 HP7.5 HP
Motor power (kW)5.5 kW5.5 kW
Fan shaft power (kW)3.93 kW3.93 kW
Average power consumption / maximum connected loadAverage: 22 kW (maximum: 30 kW)Average: 35 kW (maximum: 45 kW)
Heat capacity (kcal/h)105,000120,000
Fan design airflow (CMM, m³/min)20–12020–120
Fan design static pressure (mmAQ)40–15040–150
PREVIOUS MODEL← BSE-GP25VERPNEXT MODELBSE-GP42