KR
07DL SERIES
DRY LAMINATION · HEAT RECOVERY SYSTEM

BSE-DL22

Medium-capacity horizontal heat-recovery system for dry lamination

A dry-lamination model with a 10 HP fan, designed to maintain stable airflow and temperature across the required operating range.

Horizontal designLow-Temperature (L) / High-Temperature (H)For dry lamination
DL22E-SAVER BSE-DL22 heat recovery system
TECHNICAL SPECIFICATIONS

BSE-DL22
Technical specifications

The L/H specifications and filter dimensions below are based on E-SAVER Specification Sheet Ver. 4.6. Values may vary according to site conditions and custom-order requirements.

NoteFan design airflow and static pressure are specified separately from maximum operating values.
ItemBSE-DL22HOR-LBSE-DL22HOR-H
Applicable process equipmentDry lamination lineDry lamination line
Maximum operating temperature (°C)95℃120℃
FilterOptional
specification
Pre-filter610 × 500 × 20T
2EA
610 × 500 × 20T
2EA
Medium filter610 × 500 × 75T
2EA / D · M
610 × 500 × 75T
2EA / D · M
Optional
specification
Demister filter610 × 500 × 40T
2EA
610 × 500 × 40T
2EA
PVC bag filter320 × 615 × 5T
1EA
320 × 615 × 5T
1EA
Fan
motor
Motor rating (HP)10 HP10 HP
Motor power (kW)7.5 kW7.5 kW
Fan shaft power (kW)4.29 kW4.29 kW
Average power consumption / maximum connected loadAverage: 25 kW (maximum: 30 kW)Average: 34.125 kW (maximum: 48.75 kW)
Heat capacity (kcal/h)138,000165,000
Fan design airflow (CMM, m³/min)20–15020–150
Fan design static pressure (mmAQ)40–18040–180
PREVIOUS MODEL← BSE-DL12NEXT MODELBSE-DL32