KR
10CO SERIES
COATING PROCESS · HEAT RECOVERY SYSTEM

BSE-CO12

Horizontal heat-recovery system for medium-capacity high-temperature coating lines

A coating-line model configured for high-temperature operation, with filter and fan specifications selected to suit process conditions.

Horizontal designLow-Temperature (L) / High-Temperature (H)For coating lines
CO12E-SAVER BSE-CO12 heat recovery system
TECHNICAL SPECIFICATIONS

BSE-CO12
Technical specifications

The L/H specifications and filter dimensions below are based on E-SAVER Specification Sheet Ver. 4.6. Values may vary according to site conditions and custom-order requirements.

NoteFan design airflow and static pressure are specified separately from maximum operating values.
ItemBSE-CO12HOR-LBSE-CO12HOR-H
Applicable process equipmentCoating lineCoating line
Maximum operating temperature (°C)200℃250℃
FilterOptional
specification
Pre-filter610 × 762 × 20T
1EA
610 × 762 × 20T
1EA
Medium filter610 × 762 × 75T
1EA / M
610 × 762 × 75T
1EA / HM
Optional
specification
Demister filter610 × 762 × 40T
1EA
610 × 762 × 40T
1EA
PVC bag filter320 × 560 × 5T
1EA
320 × 560 × 5T
1EA
Fan
motor
Motor rating (HP)7.5 HP7.5 HP
Motor power (kW)5.5 kW5.5 kW
Fan shaft power (kW)3.81 kW3.81 kW
Average power consumption / maximum connected loadAverage: 50 kW (maximum: 67.5 kW)Average: 60 kW (maximum: 75 kW)
Heat capacity (kcal/h)127,000144,000
Fan design airflow (CMM, m³/min)20–10020–100
Fan design static pressure (mmAQ)60–19060–190
PREVIOUS MODEL← BSE-CO02NEXT MODELBSE-CO22